Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

A1000 - Load Reactors - Yaskawa

A1000 chassis have a built-in DC link reactor equivalent to 3% line reactance. 240 VAC ratings are shown with 3% added AC reactance for 6% total. Top 200-240V, 5% Line/Load Reactors

3-Phase Line Reactors on Single Phase Applications

The reactor must carry 12A (fundamental current) according to the NEC table for single-phase motor current. A 5% impedance is desired. For a 60Hz supply, the formula to calculate required inductance is: L = (ZV) / (377I), where L is inductance in Henries, Z is percent impedance, V is supply voltage, and I .

KDR Line / Load Reactors - Harmonic Solutions .

KDR Line Reactors are available in two ratings versions, Low "Z" (low impedance, any application where a 3% reactor would be applied) and High "Z" (high impedance, any application where a 5% reactor would be applied). Input impedance can significantly improve drive performance. Select impedance based on the guidelines below:

Trans-Coil KDRD24L | Trans-Coil KDRD24L Line Reactor, 240V .

Trans-Coil KDRD24L Line Reactor, 240V. Zoom. Mfr Number: KDRD24L. Rexel Part Number: 637578. UPC: Cut Sheet. Product Description. Line Reactor, 240V. Trans-Coil Line Reactor, 240V. Register or Log In with your Rexel Account for price or to order. For assistance, contact us.

RL Line/Load Reactors - MTE Corporation

RL Reactors Technical Reference Manual 208V – 690V 1 Form: RL-TRM-E June 2019 REV. 002 1. SAFETY Warnings and Cautions

Graco E-10 Reactor - Diamond Liners Inc.

Part Description Reactor E-10 (E-Series) Portable Proportioner Unheated ambient system, PKG. output 12 lb/min, 35' 3-Hose bundle, MD2 Cold Spray Static Mix Gun, Joint-Fill Kit, 240V, 10A, 1-Cord List Price 13,690.00

1321 Power Conditioning Products

1321-3R, 1321-3RA, and 1321-3RB Series Line Reactors 3 1321 Reflective Wave Reduction (RWR) Devices 13 1321-3TH/3TW Series Three-Phase Isolation Transformers 17 1321-Mxxx Common Mode Chokes 22 1321-DC DC Link Chokes 26. 2 Rockwell Automation Publication 1321-TD001Q-EN-P - .

Line Reactors and AC Drives

A reactor does not fix grounding issues nor does it provide isolation. Keep in mind that while a reactor provides some buffering, it does not provide isolation and can not take the place of an isolation transformer. If isolation is needed, an isolation transformer must be used. Contact your distributor for an appropriately sized transformer.

Buy KDRA25HDR-KDR, 208-240V, 5A, 1HP, 3 Phase, Open, Input .

KDRA25HDR-KDR, 208-240V, 5A, 1HP, 3 Phase, Open, Input Line Reactor, High Impedance, UL Recognized, Din Rail Mount 184.00 86.11 BUILT TO ORDER: Ships Within 3 - 5 Business Days.

350188EN, Integrated PowerStation Brochure

at 240v. Using a Reactor 2 proportioner also provides a back-up primary heat option if shore power or a temporary generator is ever desired. RE WER wer and performance. 3. Plug-and-play with Reactor 2 allows for more spray rig configuration. You can locate the Reactor 2 up to 20'

What is a line reactor and when to use it? | Wolf Automation

If a reactor is said to have an impedance rating of 3% or 5%, that means the reactor will apply that specified percent of impedance when the current flowing through the reactor is at the rated current of the device," TCI, Line and Load Reactor Basics.. Installing a line reactor on the input side of the VFD ensures protection to the drive but line reactors also have the capacity to be .

Reactor E-10 Proportioner, 240 V - Graco

The Reactor E-10 sprayers are ideal for plural-component spray, joint-fill jobs and touch-ups. With smart controls that are easy to setup and simple to operate, the E-10 is a natural complement to any proportioning equipment line-up. Small size is ideal for on-site portability and hard-to-reach areas;

GA500 - DC Reactors - Yaskawa

Large HP drives include 3% bus impedance as standard. The DC bus reactor is available loose in a separate UL Type 1 enclosure. DC Reactor Reference Documents Open DC Reactors | Enclosed DC Reactors. 240V, 1-Phase Input - 3% Bus Reactors

Line Reactors

Simply select the Horsepower, Input Voltage and Motor Type to narrow your search and find quality products that will fit your requirements.

TCI, LLC KDR Line Reactor

Impedance Options. The KDR Line Reactor has been designed to provide the best protection for both your drive and your application. KDR Line Reactors are available in two ratings versions, Low "Z" (low impedance, any application where a 3% reactor would be applied) and High "Z" (high impedance, any application where a 5% reactor would be applied).

Reactors | Transformers | Siemens Global

Series reactors are used to control current and increase impedance. As their name suggests, these reactors are arranged in series with the existing line. The series reactor constitutes an impedance in the grid and thereby increases the resistance of the network segment to limit short circuit currents or .

240VAC Line Reactors | Newark

Reactor, Core & Coil, Centurion R Series, 240 VAC, 150 hp, 3 Phase, 396 A + Check Stock & Lead Times. More stock available week commencing 6/15/20 Products not normally stocked that show available inventory, are in stock up to the quantity displayed. Additional quantities will .

Reactor E-10 Unheated Proportioner, 240 V

The Reactor E-10 sprayers are ideal for plural-component spray, joint-fill jobs and touch-ups. With smart controls that are easy to setup and simple to operate, the E-10 is a natural complement to any proportioning equipment line-up. Small size is ideal for on-site portability and hard-to-reach areas;

Load Reactor / Filter Questions - Practical Machinist

Jan 19, 2019 · 10uf per hp at 4Khz or higher frequency is more than enough for a 5% line load reactor at 240v (assuming the line/load reactor is matched for the vfd and the motor hp) in your case you have a 3% reactor so i would set the pwm to at least 6Khz and verify the reactor doesn't heat up after the capacitors are added.

Line Reactors for VFD - AC Drives | FactoryMation

Available line reactors are suitable for input and are rated for up to 104°F (40°C) ambient temperatures. These reactors are 3-phase and 600V class, feature a universal mounting footprint, and can operate at 200% rated current for a minimum of 3 minutes.

Turnigy Reaktor Pro 350W 23A Power Supply (100~240V AC)

Turnigy Reaktor Pro 350W 23A Power Supply (100~240V AC) You will earn 50 bonus points for buying this item. Turnigy Reaktor Pro 350W 23A Power Supply (100~240V AC) 25 Reviews. Price: Now save save 0.00. 0.00 . 63.48. QTY: Shipped From: USA ; Global .

Allen-Bradley / Rockwell Automation Line/Load Reactors .

1321 Power Component 100 A Line Reactor -- 1321-3RA100-A: Three-Phase Line Reactor, NEMA 1 Enclosure, 100 Amps, 0.15 mh

MTE RL Line & Load Reactors | Input/Output Reactors for VFDs

RL Line and Load Reactors Peace of mind included. Our RL Line/Load Reactors are best-in class power quality units with a long history of proven performance for lowering harmonics caused by variable frequency drives (VFDs). Rugged and robust, they are unequalled in absorbing power line disturbances that can damage or shut down variable frequency .

Reactors

The new HPS Centurion™ R reactor provides a unique blend of improved performance and reliability while reducing the product footprint. HPS Centurion™ R reactors deliver protection for your motors and drives. They are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (745 kilowatts), up to 600 V (690 V with de-rating) and are .

Line Reactor on VFD single phase input? - Practical Machinist

Dec 11, 2009 · A reactor on the VFD output will do NOTHING to control inrush current. - Leigh 12-08-2009, 09:30 PM #8. motion guru. View Profile View Forum Posts Visit Homepage Diamond Join Date Dec 2003 Country UNITED STATES State/Province Washington Posts 4,862 Post Thanks / Like Likes (Given) 2403 Likes (Received) .

Graco E-10 Reactor - Diamond Liners Inc.

Part Description Reactor E-10 (E-Series) Portable Proportioner Unheated ambient system, PKG. output 12 lb/min, 35' 3-Hose bundle, MD2 Cold Spray Static Mix Gun, Joint-Fill Kit, 240V, 10A, 1 .

Single Phase Filters | Harmonic Filters for Single Phase .

Amps Rating: 240V Open Panel Amps Rating: 240V NEMA 1 / 2 & NEMA 3R Amps Rating: 480V Open Panel Amps Rating: 480V NEMA 1 / 2 & NEMA 3R. Note: To ensure single phase compatibility, consult drive manual for proper filter sizing. Amps Rating: 240V, 60Hz Open Panel. Drawings can be accessed by clicking on the part number

AC Line Reactor | Power Quality & Conversion | Electrical .

AC Line Reactor - Three Phase, 480V 3% Impedance, 200 uH, 110 A, Encapsulated. View Details. Resource Quick View * Representative image. ALRB130CBC. By Acme Electric . Catalog ID: ALRB130CBC. AC Line Reactor - Three Phase, 480V 3% Impedance, 170 uH, 130 A. View Details. Resource Quick View * Representative image.

Graco Reactor Sprayer E-10hp (high pressure) 230V, r .

Graco Reactor E-10hp Spray Coatings Machine 230V Part #: APT901 . Get in to your own business with polyurea applications . The Reactor E-10HP is an ideal entry-level system and is great for coating projects such as balconies, pools, waterproofing and .

12ml Micro-Berty - Autoclave Engineers

CRB2HC05ZH26A Micro Berty Reactor 12 cc HC Air 240V 650ºF (343ºC) 40A-3174 40A-3173 47 CRB2HC05ZH26D Micro Berty Reactor 12 cc HC DC 240V 650ºF (343ºC) 40A-3175 40A-3173 62 CRBHT2HC05ZH26D Micro Berty Reactor 12 cc HC DC 240V 1000ºF (538ºC) 40A-7791 - .